CLOSER SIZE
|
DOOR WEIGHT
(MIN. - MAX.)
|
DOOR MEASUREMENTS
(MIN. - MAX.)
|
1
|
45 - 90 lbs (20 - 40 kg)
|
32" x 72" (80cm x 180cm)
|
2
|
55 - 100 lbs (25 - 45 kg)
|
36" x 84" (90cm x 210cm)
|
3
|
88 - 143 lbs (40 - 64 kg)
|
38" x 84" (95cm x 210cm)
|
4
|
132 - 187 lbs (60 - 84 kg)
|
42" x 96" (105cm x 243cm)
|
5
|
176 - 242 lbs (80 - 118 kg)
|
48" x 96" (120cm x 243cm)
|
6
|
266 lbs (121 kg)
|
48" x 96" (120cm x 243cm)
|
CODE REQUIREMENTS
Most Building and Fire Codes require suite
entry doors to an apartment or multi-unit dwelling have a TMFR (Twenty
Minute Fire Rated Lockset) door with a door closing device, ball bearing
hinges and equivalent fire rated lockset. All other fire and smoke barrier
doors, in any building type, require the use of a door closer device with
ball bearing hinges and a fire rated lockset or exit hardware. In the
event of a fire, this system will reduce the spread of fire and smoke
and ensure occupants sufficient time to leave building or resist injury.
Responsibility to meet Builder and Fire Codes rests with the owner, occupant
or lessee of the building. Non-compliance may result in serious fines
or imprisonment.
All 600, 500 and 1900 Series Door
Closers are C-UL and UL listed.